Step  | Action  | Value(s)  | Yes  | No  | ||||||
|---|---|---|---|---|---|---|---|---|---|---|
DEFINITION: This procedure provides a static check of all electrical wires and components in the transmission.  | ||||||||||
1  | 
 Is the resistance within the values indicated?  | 19-24ohms  | ||||||||
2  | 
 Is the resistance within the values shown?  | 19-24ohms  | ||||||||
3  | Measure the resistance between terminals B and E (2-3 Shift Solenoid valve). Is the resistance within the values indicated?  | 19-24ohms  | ||||||||
4  | 
 Is the resistance within the values shown?  | 19-24ohms  | ||||||||
5  | Measure the resistance between terminals D and E (TCC Solenoid valve). Is the resistance within the values indicated?  | 19-24ohms  | ||||||||
6  | 
 Is the resistance within the values shown?  | 19-24ohms  | ||||||||
7  | Measure the resistance between terminals C and E (TCC PWM Solenoid valve). Is the resistance within the values indicated?  | 10-12ohms  | ||||||||
8  | 
 Is the resistance within the values shown?  | 10-12ohms  | ||||||||
9  | Measure the resistance between terminals F and G (TFT Sensor). Is the resistance within the values indicated?  | 3.1-3.9Kohms  | ||||||||
10  | 
 Is the resistance within the values shown?  | 3.1-3.9Kohms  | ||||||||
11  | Measure the resistance of the internal wiring harness from pins F and G of the transmission 7-way connector to the transmission case. Is the resistance more than the value indicated?  | 20Mohms  | ||||||||
12  | Measure the resistance of the internal wiring harness from pins A, B, C, D, and E of the transmission 7-way connector to the transmission case. Is the resistance more than the value indicated?  | 250Kohms  | No problem found, exit the table  | |||||||
13  | Inspect for high resistance: 
 
 
 Was the condition found?  | --  | ||||||||
14  | Replace the internal wiring harness. Is the replacement complete?  | --  | --  | |||||||
15  | Replace the component. Is the replacement complete?  | --  | --  | |||||||