| Table 1: | Vehicle Direction Alert Alarm Warn Module Scan Tool Parameters | 
| Table 2: | Vehicle Direction Alert Alarm Warn Module Scan Tool Output Controls | 
Parameter  | System State  | Expected Value  | Definition  | 
|---|---|---|---|
Operating Conditions: Ignition ON  | |||
Battery Voltage  | --  | Varies  | The scan tool displays volts. This is the current battery voltage.  | 
Calibration Status  | --  | Inactive  | The scan tool displays Active or Inactive. Active is displayed when the VDAAW calibration is in progress.  | 
Calibration Status  | --  | Inhibit  | The scan tool displays Inhibit or OK. Inhibit is displayed when the VDAAW detects a fault in the calibration status.  | 
Diagnostic Mode  | --  | Inhibit  | The scan tool displays Inhibit or OK. Inhibit is displayed when the VDAAW detects a fault in the diagnostic mode.  | 
Mode LED  | --  | OFF  | The scan tool displays Off or On. On is displayed when the VDAAW mode LED is illuminated.  | 
Mode Switch  | --  | Inactive  | The scan tool displays Active or Inactive. This is the status of the VDAAW mode switch  | 
Operating State  | --  | OFF  | The scan tool displays Off, Disabled, Not Ready, and Ready. This is the operating state of the VDAAW module.  | 
Power Mode  | --  | OFF  | The scan tool displays Off, Run, Crank Request, and Accessory. This is the state of power for the VDAAW module.  | 
Power Mode  | --  | Inhibit  | The scan tool displays Inhibit or OK. Inhibited is displayed when VDAAW detects a fault in the power mode.  | 
Reference Voltage 1  | --  | Varies  | The scan tool displays volts.  | 
Reference Voltage 2  | --  | Varies  | The scan tool displays volts.  | 
Serial Data  | --  | Inhibit  | The scan tool displays Inhibit or OK. Inhibit is displayed when VDAAW detects a fault in the serial data.  | 
System Operation Status  | --  | Unknown  | The scan tool displays Unknown, Normal, Disabled, and Failed. This is the status of the VDAAW modules system operation.  | 
System Power Mode  | --  | Inhibit  | The scan tool displays Inhibit or OK. Inhibit is displayed when the VDAAW detects a fault in the system power mode.  | 
Scan Tool Output Control  | Description  | 
|---|---|
Calibrate Module  | This output control is used to calibrate the VDDAW module.  | 
Direction Warning Left  | This output control is used to calibrate the left sensor.  | 
Direction Warning Right  | This output control is used to calibrate the right sensor.  |