Removal Procedure
Notice: In order to avoid actuator damage, DO NOT apply power to the actuator when it is not installed in the HVAC module.
- Remove the I/P carrier. Refer to 
Instrument Panel Carrier Replacement
.
 
- Disconnect the electrical connector (4) from the right air temperature actuator (3).
 
- Remove the screws from the right air temperature actuator (3).
 
- Remove the right air temperature actuator (3) from the HVAC module assembly (2).
 
Installation Procedure
- Install the right air temperature actuator (3) from the HVAC module assembly (2).
 
Notice: Refer to Fastener Notice in the Preface section.
- Install the screws to the right air temperature actuator (3).
 
Tighten
Tighten the screws to 2 N·m (18 lb in).
- Connect the electrical connector to the right air temperature actuator.
 
- Install the I/P carrier. Refer to 
Instrument Panel Carrier Replacement
.
 
- Reprogram the air temperature actuator. Refer to 
Actuator Recalibration
.