Step  | Action  | Value(s)  | Yes  | No  | ||||
|---|---|---|---|---|---|---|---|---|
1  | Did the Horn System Check bring you here?  | --  | Go to Step 2  | Go to Horns System Check  | ||||
2  | Remove the horn relay. Do the horn(s) turn off?  | --  | Go to Step 3  | Go to Step 4  | ||||
3  | Connect a DMMJ 39200 from the horn relay CKT 28 (BLK) cavity H6 to ground. Is their continuity?  | --  | Go to Step 6  | Go to Step 5  | ||||
4  | Repair the short to battery voltage in CKT 29 (DK GRN) between the convenience center and the horn(s). Is the repair complete?  | --  | Go to Horns System Check  | --  | ||||
5  | Replace the horn relay. Refer to Horn Replacement Is the repair complete?  | --  | Go to Horns System Check  | --  | ||||
6  | 
 Did you find continuity?  | --  | Go to Step 7  | Go to Step 8  | ||||
7  | Repair the short to ground in CKT 28 (BLK) in the following locations: 
 
 Is the repair complete?  | --  | Go to Horns System Check  | --  | ||||
8  | Replace the horn switch. Is the repair complete?  | --  | Go to Horns System Check  | --  |