Removal Procedure
- Remove the upper air intake duct clamp (1).
 
- Remove the air cleaner mounting bolts (2).
 
- Remove the air cleaner assembly (3).
 
| •  | Inspect the seals for damage. | 
 
| •  | Inspect the air cleaner element for damage or excessive dirt accumulation.
Replace any part as necessary. | 
 
Installation Procedure
- Install the air cleaner assembly (3).
 
- Install the upper intake duct clamp (1).
 
Tighten
Tighten the clamp to 4 N·m (40 lb in).
- Install the air cleaner mounting bolts (2).
 
Tighten
Tighten the bolts to 11 N·m (100 lb in).