Step  | Action  | Value(s)  | Yes  | No  | 
|---|---|---|---|---|
1  | Has the Garage Door Opener System Check been performed?  | --  | Go to Step 2  | |
2  | 
 Does the test lamp light?  | --  | Go to Step 3  | Go to Step 5  | 
3  | Connect a J 35616-200 test lamp between connector C307 cavity B wire 150 (BLK) and B+. Does test lamp light?  | --  | Go to Step 4  | Go to Step 6  | 
4  | Replace the garage door opener. Refer to Garage Door Opener Module Replacement . Is the repair complete?  | --  | --  | |
5  | Locate and repair open in CKT 40 (ORN) between garage door opener and the IP fuse block. Refer to Wiring Repairs Is the repair complete?  | --  | --  | |
6  | Locate and repair open in CKT 150 (BLK) between the garage door opener and G400. Refer to Wiring Repairs Is the repair complete?  | --  | --  |