Step  | Action  | Value(s)  | Yes  | No  | 
|---|---|---|---|---|
DEFINITION: The fasten safety belt indicator does not come on during bulb check, with the driver's belt unbuckled, or with the audible alarm.  | ||||
1  | Did you review the fasten safety belt indicator circuit operation and perform the necessary inspections?  | --  | Go to Step 2  | Go to Symptoms  | 
2  | 
 Does the Fasten Safety Belt indicator illuminate?  | --  | Go to Testing for Intermittent Conditions and Poor Connections  | Go to Step 3  | 
3  | 
 Is continuity present?  | --  | Go to Step 7  | Go to Step 4  | 
4  | Connect a J 39200 DMM between multi-function alarm module connector C1 cavity C2 and instrument cluster connector cavity A12 for CKT 234 (YEL). Refer to Circuit Testing in Wiring Systems. Is continuity present?  | --  | Go to Step 5  | Go to Step 8  | 
5  | 
 Is the voltage less than the specified value?  | 10 V  | Go to Step 9  | Go to Step 6  | 
6  | Install a known good bulb in place of the safety belt lamp. Refer to Instrument Cluster Bulb Replacement in Lighting Systems. Is the fasten safety belt indicator operative?  | --  | Go to Step 10  | Go to Step 11  | 
7  | Repair the short to ground in CKT 234 (YEL) between the multi-function alarm module and the instrument cluster. Refer to Wiring Repairs in Wiring Systems. Is the repair complete?  | --  | Go to Step 12  | Go to Step 3  | 
8  | Repair the open in CKT 234 (YEL) between the multi-function alarm module and the instrument cluster. Refer to Wiring Repairs in Wiring Systems. Is the repair complete?  | --  | Go to Step 12  | Go to Step 3  | 
9  | Replace the multifunction alarm module. Refer to Multifunction Alarm Module Replacement in IP Gauges and Console. Is the repair complete?  | --  | Go to Step 12  | Go to Step 3  | 
10  | Replace the safety belt indicator lamp. Refer to Instrument Cluster Bulb Replacement in Lighting Systems. Is the repair complete?  | --  | Go to Step 12  | Go to Step 3  | 
11  | Replace the instrument cluster. Refer to Instrument Cluster Replacement in IP Gauges and Console. Is the repair complete?  | --  | Go to Step 12  | Go to Step 3  | 
12  | Operate the system in order to verify the repair. Did you correct the condition?  | --  | System OK  | Go to Step 3  |