- Remove the front wheelhouse panel.
- Partially drain the coolant. Refer to
Cooling System Draining and Filling
.
- Reposition the radiator surge tank inlet hose clamps.
- Remove the radiator surge tank inlet hose.
- Reposition the radiator surge tank outlet hose clamp.
- Remove the radiator surge tank outlet hose.
- Reposition the surge tank overflow clamp.
- Remove the surge tank overflow hose.
- Remove the radiator surge tank cap.
- Remove the radiator surge tank bolts.
- Remove the radiator surge tank from the mounting bracket.
- Inspect the radiator surge tank mounting bracket for cracks. Replace
the mounting bracket if damaged.
Installation Procedure
- Install the radiator surge tank to the mounting bracket.
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the radiator surge tank bolts.
Tighten
Tighten the bolts to 13 N·m (115 lb in).
- Install the radiator surge tank inlet hose and the
clamps.
- Install the radiator surge tank outlet hose and the clamps.
Tighten
Tighten the clamps to 3 N·m (27 lb in).
- Install the surge tank overflow hose and the clamp.
- Install the front wheelhouse panel.
- Fill the cooling system. Refer to
Cooling System Draining and Filling
.