| Table 1: | Generator C2 (L18) |
| Table 2: | Generator C2 (LG5) |
| Table 3: | Generator Inline Fuse |
| Table 4: | Starter Relay |
| Table 5: | Starter Temperature Switch |
| |||||||
|---|---|---|---|---|---|---|---|
Connector Part Information |
| ||||||
Pin | Wire Color | Circuit No. | Function | ||||
A | PPL | 1477 | Generator Output Tachometer Pulse | ||||
B | RED | 225 | Generator Turn On Signal | ||||
C | GRY | 23 | Generator Field Duty Cycle Signal | ||||
D | RED | 442 | Battery Positive Voltage | ||||
| |||||||
|---|---|---|---|---|---|---|---|
Connector Part Information |
| ||||||
Pin | Wire Color | Circuit No. | Function | ||||
A | RED | 442 | Fuse Output-Battery | ||||
B | BRN | 25 | Charge Indicator Lamp Output | ||||
| |||||||
|---|---|---|---|---|---|---|---|
Connector Part Information |
| ||||||
Pin | Wire Color | Circuit No. | Function | ||||
A | YEL | 53 | Fuse Output Generator Tachometer Pulse Type III Fuse | ||||
B | PPL | 1477 | Generator Output Tachometer Pulse | ||||
| |||||||
|---|---|---|---|---|---|---|---|
Connector Part Information |
| ||||||
Pin | Wire Color | Circuit No. | Function | ||||
30 | PPL | 6 | Starter Solenoid Crank Voltage | ||||
85 | PPL | 806 | Crank Voltage (L18) | ||||
85 | ORN/BLK | 434 | Neutral Safety Switch Signal (LG5) | ||||
86 | YEL | 447 | Starter Relay Coil Control (L18) | ||||
86 | BLK | 650 | Ground (LG5) | ||||
87 | RED | 2 | Battery Positive Voltage | ||||
| |||||||
|---|---|---|---|---|---|---|---|
Connector Part Information |
| ||||||
Pin | Wire Color | Circuit No. | Function | ||||
A | ORN/BLK | 434 | Neutral Safety Switch Signal | ||||
B | ORN/BLK | 434 | Neutral Safety Switch Signal | ||||