Step | Action | Yes | No |
|---|---|---|---|
Schematic Reference: Suspension Controls Schematics | |||
1 | Did you review the system and circuit description and perform the necessary inspections? | Go to Step 2 | |
2 | Verify the fault is present. Does the system operate normally? | Go to Testing for Electrical Intermittents in Wiring Systems | Go to Step 3 |
3 |
Does the test lamp illuminate? | Go to Step 4 | Go to Step 5 |
4 |
Does the test lamp illuminate? | Go to Step 7 | Go to Step 6 |
5 | Check the air suspension dump switch indicator lamp ground circuit for an open. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 8 | -- |
6 | Check the air suspension dump valve control circuit for an open between the air suspension dump switch and the splice. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 8 | -- |
7 | Replace the bulb in the rocker switch or replace the air suspension dump switch. Did you complete the replacement? | Go to Step 8 | -- |
8 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 3 |