Step | Action | Yes | No |
|---|---|---|---|
Schematic Reference: Power Window Schematics DEFINITION:This diagnostic procedure should be used to diagnose a total failure of the power window system. | |||
1 | Did you review the Power Window Description and Operation and perform the necessary inspections? | Go to Step 2 | Go to Symptoms - Doors |
2 |
Do both power windows operate up and down from both switches? | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 3 |
3 | Did either power window operate from either switch? | Go to Power Window Inoperative - Driver Door or Power Window Inoperative - Passenger Door | Go to Step 4 |
4 |
Does the test lamp illuminate? | Go to Step 5 | Go to Step 6 |
5 | Connect the test lamp between the power window master switch ground circuit and B+. Does the test lamp illuminate? | Go to Step 10 | Go to Step 16 |
6 |
Did the test lamp illuminate? | Go to Step 7 | Go to Step 12 |
7 |
Did the test lamp illuminate? | Go to Step 8 | Go to Step 18 |
8 | Connect a test lamp between the power window relay ground circuit and the ignition 3 voltage circuit at the convenience center. Did the test lamp illuminate? | Go to Step 9 | Go to Step 14 |
9 |
Do the power windows operate properly? | Go to Step 11 | Go to Step 13 |
10 | Inspect for poor connections at the power window master switch. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 19 | Go to Step 15 |
11 | Inspect for poor connections at the power window relay. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 19 | Go to Step 17 |
12 | Repair the open or short to ground in the power window relay battery voltage supply circuit. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you complete the repair? | Go to Step 19 | -- |
13 | Repair the open or short to ground in the power window switch battery voltage supply circuit. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you complete the repair? | Go to Step 19 | -- |
14 | Repair the open in the power window relay ground circuit. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you complete the repair? | Go to Step 19 | -- |
15 | Replace the power window master switch. Did you complete the repair? | Go to Step 19 | -- |
16 | Repair the open in power window master switch ground circuit. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you complete the repair? | Go to Step 19 | -- |
17 | Replace the power window relay. Did you complete the repair? | Go to Step 19 | -- |
18 | Repair the open in the power window switch battery positive voltage circuit. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you complete the repair? | Go to Step 19 | -- |
19 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 3 |