Step | Action | Yes | No |
|---|---|---|---|
Schematic Reference: HVAC Schematics DEFINITION: The blower motor is ON while the blower motor switch is in the OFF position. | |||
1 | Did you review the HVAC operation and perform the necessary inspections? | Go to Step 2 | |
2 |
Is the blower motor OFF? | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 3 |
3 |
Is the blower motor OFF? | Go to Step 5 | Go to Step 4 |
4 |
Is the blower motor OFF? | Go to Step 11 | Go to Step 13 |
5 |
Does the test lamp illuminate at any control circuit? | Go to Step 7 | Go to Step 6 |
6 |
Is the blower motor operating in high speed? | Go to Step 9 | Go to Step 8 |
7 | Test the appropriate blower motor speed control circuit for a short to ground. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 17 | Go to Step 10 |
8 | Inspect for poor connections at the harness connector of the blower motor 1 relay. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 17 | Go to Step 14 |
9 | Inspect for poor connections at the harness connector of the blower motor 2 relay. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 17 | Go to Step 15 |
10 | Inspect for poor connections at the harness connector of the HVAC control module or blower motor switch if not equipt with A/C. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 17 | Go to Step 16 |
11 | Test the blower motor resistor supply voltage circuit for a short to voltage. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 17 | Go to Step 12 |
12 | Repair the short to voltage in the medium blower motor supply circuit between the blower motor resistor assembly and the blower motor 2 relay. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you complete the repair? | Go to Step 17 | -- |
13 | Repair the short to voltage in the blower motor supply voltage circuit. Refer to Wiring Repairs in Wiring Systems. Did you complete the repair? | Go to Step 17 | -- |
14 | Replace the blower motor 1 relay. Did you complete the replacement? | Go to Step 17 | -- |
15 | Replace the blower motor 2 relay. Did you complete the replacement? | Go to Step 17 | -- |
16 | Replace the HVAC control module or blower motor switch if not equipt with A/C. Refer to HVAC Control Module Replacement or Blower Motor Switch Replacement . Did you complete the replacement? | Go to Step 17 | -- |
17 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 2 |