Step | Action | Value(s) | Yes | No | ||||||
|---|---|---|---|---|---|---|---|---|---|---|
1 |
Is the resistance within the values indicated? | 19-24 ohms at 20°C (68°F) 24-31 ohms at 88°C (190°F) | ||||||||
2 |
Is the resistance within the values indicated? | 19-24 ohms at 20°C (68°F) 24-31 ohms at 88°C (190°F) | ||||||||
3 | Measure the resistance between terminals B and E (2-3 Shift Solenoid Valve). Is the resistance within the values indicated? | 19-24 ohms at 20°C (68°F) 24-31 ohms at 88°C (190°F) | ||||||||
4 |
Is the resistance within the values indicated? | 19-24 ohms at 20°C (68°F) 24-31 ohms at 88°C (190°F) | ||||||||
5 | Measure the resistance between terminals T and E (TCC PWM Sol. Valve). Is the resistance within the values indicated? | 10-12 ohms at 20°C (68°F) 13-15 ohms at 88°C (190°F) | ||||||||
6 |
Is the resistance within the values indicated? | 10-12 ohms at 20°C (68°F) 13-15 ohms at 88°C (190°F) | ||||||||
7 | Measure the resistance between terminals C and D (PC Sol. Valve). Is the resistance within the values indicated? | 3-5 ohms at 20°C (68°F) 5-6 ohms at 88°C (190°F) | ||||||||
8 |
Is the resistance within the values indicated? | 3-5 ohms at 20°C (68°F) 5-6 ohms at 88°C (190°F) | ||||||||
9 | Measure the resistance between terminals S and V (ISS). Is the resistance within the values indicated? | 893-1127 ohms at 20°C (68°F) 1132-1428 ohms at 88°C (190°F) | ||||||||
10 |
Is the resistance within the values indicated? | 893-1127 ohms at 20°C (68°F) 1132-1428 ohms at 88°C (190°F) | ||||||||
11 | Measure the resistance between terminals M and L (TFT). Is the resistance within the values indicated? | 3164-3867 ohms at 20°C (68°F) 225-285 ohms at 88°C (190°F) | ||||||||
12 |
Is the resistance within the values indicated? | 3164-3867 ohms at 20°C (68°F) 225-285 ohms at 88°C (190°F) | ||||||||
13 | Using the J 39200 DMM and the J 35616-A Connector Test Adapter Kit, measure the resistance of the automatic transmission wiring harness from pins A, B, C, D, E, and T of the transmission 20-way connector to the transmission case. Is the resistance more than shown? | 250 K ohms | ||||||||
14 | Using the J 39200 DMM and the J 35616-A Connector Test Adapter Kit, measure the resistance of the automatic transmission wiring harness from pins L and M of the transmission 20-way connector to the transmission case. Is the resistance more than shown? | 20 M ohms | ||||||||
15 | Using theJ 39200 DMM and the J 35616-A Connector Test Adapter Kit, measure the resistance of the automatic transmission wiring harness from pins S and V of the transmission 20-way connector to the transmission case. Is the resistance more than shown? | 10 M ohms | System OK | |||||||
16 | Inspect for high resistance:
Was the condition found and corrected? | -- | ||||||||
17 | Replace the automatic transmission wiring harness. Is the replacement complete? | -- | -- | |||||||
18 | Replace the component. Is the replacement complete? | -- | -- |